Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. DATE: 11/26/2025 ADDRESS: 1342 W MENDOZA AVE MESA DAMAGE CAUSED BY: Fire INSPECTED BY: Richard Lemcke The inspection of the site identified the following: Please note that before a damage permit is issued an estimate showing the Company doing the work, the subject address, scope of work, materials, and labor from either the contractor or the insurance company will be required. A written scope of work is required to approximate the cost of the permit, verbal estimations shall not be used. This structure is to be restored like for like in compliance with 2017 NEC, 2018 IRC/IBC requirements. Any alterations or changes will require submitting plans before any restoration can begin. During the damage inspection the following was observed: Structural members were damaged by and will need stamped engineering. Electrical sustained damage to several home runs, panel may not need to be replaced unless it can?t accommodate the requirements needed to comply with 2018 IRC/IBC and/or 2017 NEC. Mechanical equipment/ducts sustained minor damage. Will need to clean/repair ductwork Minor damage to plumbing, some pipes will need to be replaced or repaired. Note: Any structural members charred to a depth of 1/8” or greater are to be replaced. All plumbing, electrical and mechanical systems damaged by heat are to be replaced. A. Building is: Residential B. Building permits and inspections are required for the following phase(s) of construction: 1. Structural Yes 2 Electrical Yes 3. Mechanical Yes 4. Plumbing No 5. Construction Plans Required No Electrical service can be restored under the following conditions: Restoring power for landscaping, pool and restoration repairs. Ok to release electric. Contractor responsible for lock out tag out and any damages resulting from the power being turned on. Failure to obtain a full permit in 30 days may result in the removal of power. Natural gas service can only be restored after a gas test has been approved by the building inspector.
01342 W MENDOZA AVE
Property record
- Property type:
- RESIDENTIAL
- Year built:
- 1978
- Living area:
- 1,846 sqft
- Total sqft:
- 10,106
- Subdivision:
- DOBSON RANCH UNIT 3
- Assessed value:
- $39,680
- Full cash value:
- $396,800
Owner of record
SHELLEY STEWART B/CLAIRE K TR
542 S HIGLEY RD UNIT 81, MESA AZ 85206
APN 30507065 · Maricopa County Assessor
Water supply
- Management area:
- Phoenix AMA
- Water provider:
- City Of Mesa
Arizona Department of Water Resources
Owner portfolio
Other Maricopa parcels owned by SHELLEY STEWART B/CLAIRE K TR
Owns 3 Maricopa parcels · ~$859,900 full-cash value.
- 1342 W EMERALD AVE 365 · $244,100
- 1342 W EMERALD AVE 411 · $219,000
Neighborhood
- Owner-occupied:
- 50% of homes
- Median home value:
- $334,200
- Median household income:
- $66,582
- Median year built:
- 1979
ZIP 85202 · U.S. Census ACS 2023 5-year
Permits (1, last 90 days)
HOTBefore demolition or restoration can begin, an approved method of trash containment and removal must be in place.
DATE: 11/26/2025
ADDRESS: 1342 W MENDOZA AVE MESA
DAMAGE CAUSED BY: Fire
INSPECTED BY: Richard Lemcke
The inspection of the site identified the following: Please note that before a damage permit is issued an estimate showing the
Company doing the work, the subject address, scope of work, materials, and labor from either the contractor or the
insurance company will be required. A written scope of work is required to approximate the cost of the permit, verbal
estimations shall not be used. This structure is to be restored like for like in compliance with 2017 NEC, 2018 IRC/IBC
requirements. Any alterations or changes will require submitting plans before any restoration can begin. During the
damage inspection the following was observed: Structural members were damaged by and will need stamped
engineering. Electrical sustained damage to several home runs, panel may not need to be replaced unless it can?t
accommodate the requirements needed to comply with 2018 IRC/IBC and/or 2017 NEC. Mechanical equipment/ducts
sustained minor damage. Will need to clean/repair ductwork Minor damage to plumbing, some pipes will need to be
replaced or repaired.
Note: Any structural members charred to a depth of 1/8” or greater are to be replaced. All plumbing, electrical and mechanical
systems damaged by heat are to be replaced.
A. Building is: Residential
B. Building permits and inspections are required for the following phase(s) of construction:
1. Structural Yes
2 Electrical Yes
3. Mechanical Yes
4. Plumbing No
5. Construction Plans Required No
Electrical service can be restored under the following conditions: Restoring power for landscaping, pool and restoration
repairs. Ok to release electric. Contractor responsible for lock out tag out and any damages resulting from the power
being turned on. Failure to obtain a full permit in 30 days may result in the removal of power.
Natural gas service can only be restored after a gas test has been approved by the building inspector.
Permit #PMT26-12378 · mesa · issued Jul 7, 2026