Construction of 299 sq ft livable addition with attached 65 sq ft storage under new awning with ceiling joists, electric and plumbing for bathroom, washer/dryer on raised deck. New 187 sq ft parking area and 110 sq ft exterior covered deck. Awning engineering provided by Carl Putnam, no. 39702, expires 9/30/27.Type V-B construction. No deferred items. No special inspections. Minimum of one 9-ft x 18-ft unobstructed paved parking space required behind front setback on 2-in asphalt or 4-in concrete. Minimum setbacks are 5-ft front measured from edge of asphalt, 3-ft rear for interior spaces, 3-ft PM side, 0-ft awning or carport side, and street side always 3-ft. Accessory structures do not exceed 100 percent of the Park Model floor area. Accessory structures shall be removed within 60 days of removal of the Park Model. Per section 11-34-2.a of the Mesa Zoning Ordinance, amended in July 2025. Reference PMT26-08774. Minimum required inspections - footing, stem, strap and sheer, frame, mechanical rough-in, electric rough-in, plumbing rough-in, insulation, drywall shear and final. If needed, underground plumbing. Approved as noted.
Maricopa County · APN 14017005A
5055 E UNIVERSITY DR J21
Mesa, AZ, 85205 · Residential
Permit applied — not yet issued
Filed 25d ago · in the typical ~16d issue window now — quote before it pulls
Based on mesa's typical applied→issued time — the earliest a supplier can engage, before the slab is poured.
Property record
- Property type:
- RESIDENTIAL
- Year built:
- 1982
- Total sqft:
- 1,452,980
- Assessed value:
- $1,238,228
- Full cash value:
- $12,382,281
Water supply
- Management area:
- Phoenix AMA
- Water provider:
- City Of Mesa
Sales history
- Jan 1, 2002$19,200,000SD
Neighborhood
- Owner-occupied:
- 72% of homes
- Median home value:
- $301,200
- Median household income:
- $71,294
- Median year built:
- 1986
Permits (3, last 90 days)
Construction of 297 sq ft livable addition under awning with ceiling joists, electric and plumbing for bathroom, washer and dryer on raised deck and 138 sq ft covered deck and awning. Minimum of one 9-ft x 18-ft unobstructed paved, 2-in asphalt or 4-in concrete, parking space required behind front setback. 33.5-ft x 49.5-ft interior corner lot. Minimum setbacks are 5-ft front measured from edge of asphalt, 3-ft rear, 0-ft pm side & 3-ft awning or carport side. Accessory structure roof areas do not exceed 100 percent of the Park Model floor area. Reference PMT24-09765 for existing 2026 Cavco Tuscany park model. Accessory structure shall be removed within 60 days of removal of the park model. Minimum required building inspections: Footing, stem, strap/shear, frame, insulation, drywall shear and final. If needed, underground electrical and plumbing. Approved as noted.
Showing the last 90 days — Pro shows the full history. See pricing
Want to see permits older than 90 days? Sign up free.
Sign up — 14-day Pro trial