Skip to main content
Plumb Intelligence

Maricopa County · APN 14017005A

5055 E UNIVERSITY DR G4

Mesa, AZ, 85205 · Residential

3 permits on record
Applied

Permit applied — not yet issued

Filed 25d ago · in the typical ~16d issue window now — quote before it pulls

Based on mesa's typical applied→issued time — the earliest a supplier can engage, before the slab is poured.

Property record

Property type:
RESIDENTIAL
Year built:
1982
Total sqft:
1,452,980
Assessed value:
$1,238,228
Full cash value:
$12,382,281
Owner of record
SUN LIFE RVR LLC
APN 14017005A · Maricopa County Assessor

Water supply

Management area:
Phoenix AMA
Water provider:
City Of Mesa
Arizona Department of Water Resources

Sales history

  • Jan 1, 2002$19,200,000SD
Maricopa County sales affidavits · sale dates resolve to month

Neighborhood

Owner-occupied:
72%
of homes
Median home value:
$301,200
Median household income:
$71,294
Median year built:
1986
ZIP 85205 · U.S. Census ACS 2023 5-year · This product uses the Census Bureau Data API but is not endorsed or certified by the Census Bureau.

Permits (3, last 90 days)

HOTConstruction of 299 sq ft livable addition with attached 65 sq ft storage under new awning with ceiling…
Permit #PMT26-15081 · mesa · issued Oct 14, 2026
$85,264
Issued

Construction of 299 sq ft livable addition with attached 65 sq ft storage under new awning with ceiling joists, electric and plumbing for bathroom, washer/dryer on raised deck. New 187 sq ft parking area and 110 sq ft exterior covered deck. Awning engineering provided by Carl Putnam, no. 39702, expires 9/30/27.Type V-B construction. No deferred items. No special inspections. Minimum of one 9-ft x 18-ft unobstructed paved parking space required behind front setback on 2-in asphalt or 4-in concrete. Minimum setbacks are 5-ft front measured from edge of asphalt, 3-ft rear for interior spaces, 3-ft PM side, 0-ft awning or carport side, and street side always 3-ft. Accessory structures do not exceed 100 percent of the Park Model floor area. Accessory structures shall be removed within 60 days of removal of the Park Model. Per section 11-34-2.a of the Mesa Zoning Ordinance, amended in July 2025. Reference PMT26-08774. Minimum required inspections - footing, stem, strap and sheer, frame, mechanical rough-in, electric rough-in, plumbing rough-in, insulation, drywall shear and final. If needed, underground plumbing. Approved as noted.

661 sq ftHarte Contracting Services LLC (Verified)
HOTbuild az room and deck
Permit #PMT26-17528 · mesa · applied Sep 30, 2026
~$26,432est
Revisions Required
0
WARMConstruction of 297 sq ft livable addition under awning with ceiling joists, electric and plumbing for…
Permit #PMT26-11290 · mesa · issued Jul 30, 2026
$68,135
Issued

Construction of 297 sq ft livable addition under awning with ceiling joists, electric and plumbing for bathroom, washer and dryer on raised deck and 138 sq ft covered deck and awning. Minimum of one 9-ft x 18-ft unobstructed paved, 2-in asphalt or 4-in concrete, parking space required behind front setback. 33.5-ft x 49.5-ft interior corner lot. Minimum setbacks are 5-ft front measured from edge of asphalt, 3-ft rear, 0-ft pm side & 3-ft awning or carport side. Accessory structure roof areas do not exceed 100 percent of the Park Model floor area. Reference PMT24-09765 for existing 2026 Cavco Tuscany park model. Accessory structure shall be removed within 60 days of removal of the park model. Minimum required building inspections: Footing, stem, strap/shear, frame, insulation, drywall shear and final. If needed, underground electrical and plumbing. Approved as noted.

432 sq ftHarte Contracting Services LLC (Verified)

Showing the last 90 days — Pro shows the full history. See pricing

Want to see permits older than 90 days? Sign up free.

Sign up — 14-day Pro trial