New development of a 4-story, 103-unit, 54,770 SF, type V-A construction, R-1, A-2, A-3, B and S-1 occupancy Candlewood suites hotel. Special inspection req. steel, concrete, masonry, special cases - post-installed anchors, soils. EIFS and Fire resistant penetrations & Joints, elect equip rated at or above 1,000amps. Deferred Wood truss. Deferred fire sprinklers, fire alarm/detection systems, access control. Site water and sewer to be by City of Tempe. REF: PMT26-03590 Approved Civil/ Landscape Plans. REF: PMT26-11181 Den Housing. Results in CoO.
Maricopa County · APN 13538001N
2630 W RIO SALADO PKWY
Mesa, AZ, 85201 · Commercial
Permit applied — not yet issued
Filed 26d ago · in the typical ~16d issue window now — quote before it pulls
Based on mesa's typical applied→issued time — the earliest a supplier can engage, before the slab is poured.
Property record
- Property type:
- COMMERCIAL
- Total sqft:
- 110,250
- Assessed value:
- $338,805
- Full cash value:
- $2,258,700
Neighborhood
- Owner-occupied:
- 39% of homes
- Median home value:
- $292,600
- Median household income:
- $63,725
- Median year built:
- 1981
Permits (4, last 90 days)
THIS IS A USE PERMIT FOR A TEMPORARY CONSTRUCTION FIELD OFFICE TRAILER FOR USE BY CONTRACTORS WHILE A PERMANENT BUILDING IS UNDER CONSTRUCTION. THE CONSTRUCTION TRAILER MUST BE PLACED ONLY ON THE PROPERTY THAT IS BEING DEVELOPED AND OUT OF ALL BUILDING SETBACKS. NO PUBLIC USE IS PERMITTED. THIS USE PERMIT SHALL BE NON-TRANSFERABLE FROM ONE OWNER OR LESSEE TO ANOTHER AND SHALL EXPIRE ON DECEMBER 31, OF EACH YEAR UNLESS EARLIER REVOKED. ESTIMATED TIME OF CONSTRUCTION TRAILER REMOVAL IS NOVEMBER 30, 2027. PERMIT INCLUDES TEMPORARY ELECTRIC. REFERENCE PARENT PERMIT NUMBER - PMT26-03590 PROJECT NAME - THE DEN ON RIO SALADO
0New development of a 5-story, 36-unit, 64,594 gross SF (50,813 net SF), type III-A construction, R-2 occupancy multifamily apartment building with site improvements including parking, accessible routes, site lighting, trash enclosure, sidewalks, striping, and signage. Installation of all off-site improvements and street frontage landscaping during the first phase of construction. Special inspection req. steel, concrete, masonry, special cases - post-installed anchors, soils. EIFS and Fire resistant penetrations & Joints, elect equip rated at or above 1,000amps. Special Inspections Req - Emergency Responder Radio Coverage IFC 510. Deferred Wood truss. Deferred fire sprinklers and standpipe system, fire alarm, access control, and electric vehicle gates. Site water and sewer to be by City of Tempe. REF: PMT26-03590 Approved Civil/ Landscape Plans. REF: PMT26-11246 Candlewood suites. Approved with comments. Results in CoO.
Showing the last 90 days — Pro shows the full history. See pricing