Maricopa County · APN 14065222A
1854 S VAL VISTA DR 101
Mesa, AZ, 85204 · Commercial
Permit applied — not yet issued
Filed 8d ago · typically issues ~16d after filing (≈8d out)
Based on mesa's typical applied→issued time — the earliest a supplier can engage, before the slab is poured.
Property record
- Property type:
- COMMERCIAL
- Year built:
- 2003
- Total sqft:
- 988,686
- Subdivision:
- DANA PARK VILLAGE SQUARE LOTS 7 THRU 9
- Assessed value:
- $4,422,926
- Full cash value:
- $29,486,173
Water supply
- Management area:
- Phoenix AMA
- Water provider:
- City Of Mesa
Sales history
- Sep 1, 2012$46,500,00000
Neighborhood
- Owner-occupied:
- 58% of homes
- Median home value:
- $296,000
- Median household income:
- $69,474
- Median year built:
- 1980
Permits (6, last 90 days)
Install (1) wall mounted illuminated sign with channel lettering: WHITE HOUSE BLACK MARKET - 54 sf and one door sign WHBM - 5 sq ft.
Group M occupancy. Type II-B Construction. 3,853 SF. Occupant load 54. Demo marked portion of demising wall to give space to adjacent suite. Demo storefront system, storefront column, partition walls, plumbing fixtures, floor drains, electrical panel, portion of slab for electrical trenching, existing RTUs, mechanical ducting, electrical lighting, and ceiling. Partition walls at existing restroom and structural column to remain. New 1-hr rated demising wall at adjacent suite. New partition walls to create storage area, fitting rooms, and office. 3-new mechanical RTU heat pumps. New mechanical supply air ducting, return air ducting, diffusers, return air grilles, electrical panel, and storefront glazing system. New plumbing fixtures at restroom. New architectural, structural, and MEPs. Approved with Stipulation at sheet A1.31. Special inspections required: field welding and concrete construction. Deferred submittal: fire sprinklers and exterior awning. Results in CofO.
Group M occupancy. Type II-B construction. 3,000 SF. Occupant load 42. Demo marked portion of demising wall to give space to adjacent suite. Demo storefront system, storefront column, partition walls, plumbing fixtures, floor drains, electrical panel, portion of slab for electrical trenching, soffit and columns, existing RTUs, mechanical ducting, electrical lighting, and ceiling. New 1-hr rated demising wall at storage area. New partition walls to create storage area, ADA compliant restroom, and vestibule. 2-new mechanical RTU heat pumps. New mechanical supply air ducting, return air ducting, diffusers, return air grilles, electrical panel, and storefront glazing system. New plumbing fixtures at restroom. New architectural, structural, and MEPs. Special inspections required: field welding and epoxy. Deferred fire sprinklers. Results in CofO.
Showing the last 90 days — Pro shows the full history. See pricing
Want to see permits older than 90 days? Sign up free.