Skip to main content
Plumb Intelligence

Maricopa County · APN 13909548

1830 E BASELINE RD 101

Mesa, AZ, 85204 · Commercial

3 permits on record

Property record

Property type:
COMMERCIAL
Year built:
1989
Total sqft:
316,885
Subdivision:
MESA COMMONS PARCEL 1 AND 5 LOT SPLIT
Assessed value:
$1,723,544
Full cash value:
$11,490,297
Owner of record
SCHNEIDER DAVID/ETAL
APN 13909548 · Maricopa County Assessor

Water supply

Management area:
Phoenix AMA
Water provider:
City Of Mesa
Arizona Department of Water Resources

Neighborhood

Owner-occupied:
58%
of homes
Median home value:
$296,000
Median household income:
$69,474
Median year built:
1980
ZIP 85204 · U.S. Census ACS 2023 5-year · This product uses the Census Bureau Data API but is not endorsed or certified by the Census Bureau.

Permits (3, last 90 days)

WARMModifications to existing ANSUL System for proper coverage of existing tilt skillet in kitchen of an existing…
Permit #PMT26-12341 · mesa · issued Aug 3, 2026
$3,000
Issued

Modifications to existing ANSUL System for proper coverage of existing tilt skillet in kitchen of an existing indoor amusement building. Adding 1 new 1.5 gallon cylinder, 1 new 3N nozzle over Tilt Skillet. System and hood are all existing. Results in CofC.

0Metro Fire Equipment Inc (Likely)
WARMInstall (2) hood suppression systems. System 1 Ansul consists of (1) 3-gal wet chemical cylinder supporting…
Permit #PMT19-14977 · mesa · issued Jul 13, 2026
$500
Issued

Install (2) hood suppression systems. System 1 Ansul consists of (1) 3-gal wet chemical cylinder supporting (2) 1-flow point head in ducts, (2) 1-flow point head in plenum, (1) 1-flow point head over Charboiler, and (3) 2-flow point head over Tilt Skillet. System 2 Range Guard consists of (1) 4-gal wet chemical cylinder and (1) 1.25-gal wet chemical cylinder supporting (2) 1-flow point heads in duct, (2) 1-flow point heads in plenum, (2) 2-flow point heads over the fryers, (1) 1-flow point heads in salamander, and (2) 2-flow point heads over 6-burner range. System also has two manual pull stations, emergency gas/electric shut off valves and is connected to the fire sprinkler monitoring panel. Fusible links rated at 450°F. Signs placed over each hood and manual pull station indicating which hood associates with corresponding manual pull station.

0Metro Fire Equipment Inc (Likely)
WARMTenant improvement area 22,325 SF in existing 87,057 SF, type III-B construction, A-3 occupancy Family…
Permit #PMT26-04203 · mesa · issued Jun 23, 2026
$18,498,133
Issued

Tenant improvement area 22,325 SF in existing 87,057 SF, type III-B construction, A-3 occupancy Family entertainment center. Modifications include reconfigurations of attractions, new go-kart track and prize store. No food and beverage alterations, no change of occupancy, no building addition and no exterior building changes are proposed. Special inspection req. steel, concrete, fabricated items, structural observation. Deferred fire sprinklers and fire alarm. Approved with comments. Results in CoO.