Group B Occupancy. Type II-B construction. 5,456 SF. Occupant load 107. Modification of existing business office suite. Demo identified partition walls and doors. New partition walls, doors, demising wall. To create new conference room and (2) additional offices. Demo identified mechanical air supply ducting. Relocate identified diffusers and grilles. New mechanical supply air ducting. New water supply line from existing to new water valve box in breakroom for a refrigerator. Additional new lighting. Demo identified electrical. New electrical receptacles, outlets, and junction boxes. Deferred fire sprinklers and fire alarm. Results in CofO.
Maricopa County · APN 13911004J
1640 S STAPLEY DR 132
Mesa, AZ, 85204 · Commercial
Permit applied — not yet issued
Filed 52d ago · well past the typical ~16d window — likely revising or phased
Based on mesa's typical applied→issued time — the earliest a supplier can engage, before the slab is poured.
Property record
- Property type:
- COMMERCIAL
- Year built:
- 2000
- Total sqft:
- 833,311
- Assessed value:
- $7,532,894
- Full cash value:
- $50,219,297
Water supply
- Management area:
- Phoenix AMA
- Water provider:
- City Of Mesa
Sales history
- Aug 1, 2018$48,500,000SD
Neighborhood
- Owner-occupied:
- 58% of homes
- Median home value:
- $296,000
- Median household income:
- $69,474
- Median year built:
- 1980
Permits (7, last 90 days)
Tenant improvement in existing 3,290 SF, type II-B construction, B occupancy office suite. Modifications include interior non-bearing partition demo, light fixture, millwork and mech duct removal for new suite layout to modify existing breakroom and reception area and create new conference room , collaboration area, IT and storage room. Existing shared building common restroom facility to remain. Modification include new ductwork from existing units, lighting and power. Deferred fire sprinklers and fire alarm. Results in CoO.
Tenant improvement in existing 4,982 SF, type II-B construction, group B occupancy suite. Modifications include new demising wall to split suite, minor demo and new partitions in exist occupied suite, new millwork and finishes and associated MEP scope. Deferred fire sprinklers and fire alarms. Access Control to be under a separate submittal. Remaining suite to be vacant/unoccupied. Results in CoO.
Tenant improvement of existing type II-B construction, B occupancy suite. Modification include minor demolition and new demising wall partition to reduce suite SF to 3,334 SF. Existing ceiling grid and tile to remain throughout, minor lighting relocation to suit new layout. Minor mechanical and electrical modifications to suit new layout. Deferred fire alarm. Results in CoO.
TI to create a new 14,294 SF suite in an existing construction type II-B multistory office building. Scope includes interior demo, new partition walls MEP's and finishes. Deferred fire sprinklers, fire alarm, and access control. Reviewed as noted. Results in CoO.
Group B occupancy. Type II-B construction. 6,506 SF. Occupant load 90. Demo identified existing interior partitions at new conference room. New architectural and electrical. Install new glazing and partition wall at new conference room. Core and install (2) new electrical floor receptacles at conference room. Relocate identified existing return air grilles and supply air diffusers as noted. (6) existing heat pump RTUs with duct mounted smoke detectors and condensate drains to remain. Existing ADA compliant restrooms within 500 feet of travel distance from the suite meet required minimum plumbing fixture calculations. No exterior modifications included in this permit. The replacement or addition of signs on the site will require the review and approval of a separate permit. Deferred fire sprinklers and fire alarm. Results in CofO.
Second floor corridor extension on an existing 99,186 SF office building, type II-B construction. Scope includes demolition of existing interior partitions, doors, frames, hardware, sidelights, and new partitions, doors, frames, hardware, light fixtures, ceiling grid, tile and drywall ceiling to suit new layout. Minor MEP modifications and new finishes. Deferred fire sprinklers, fire alarm and access control. Reviewed as noted. Results in CoC.
Showing the last 90 days — Pro shows the full history. See pricing