New detached garage structures consisting of (4) G10 garage buildings and (2) G9HC garage buildings. G10 buildings are Type V-B construction, Group S-2 occupancy, totaling 2,404 SF each. G9HC buildings are Type V-B construction, Group S-2 occupancy, totaling 2,271 SF each. Scope includes architectural, structural, and electrical systems. Deferred fire sprinkler system and truss calculations. Separate permit to be submitted for sprinkler monitoring. Special inspections required for soils, concrete, and fire-resistance-rated assemblies. Results in a CoO.
Maricopa County · APN 22082018L
1345 S SIGNAL BUTTE RD
Mesa, AZ, 85209 · Vacant
Property record
- Property type:
- VACANT
- Total sqft:
- 589,213
- Assessed value:
- $890,580
- Full cash value:
- $5,937,200
Water supply
- Management area:
- Phoenix AMA
- Water provider:
- City Of Mesa
Sales history
- Aug 1, 2024$7,400,000CASHSD
Neighborhood
- Owner-occupied:
- 74% of homes
- Median home value:
- $363,800
- Median household income:
- $80,498
- Median year built:
- 2000
Permits (13, last 90 days)
BLDG 4: New 3-story, type V-A construction, 31,104 SF, group R-2, 24 unit Multifamily building. Special inspection req. - concrete, soils, Fire-resistant penetration & joints. Deferred submittal: Roof trusses. Deferred 13R fire sprinklers, and fire alarm. REF: PMT25-21560 for civil improvement and water meters. Approved with comments. Results in CoO.
New Building of 276-units multi-family development comprising of (9) 3-stories multifamily buildings. BLDG 7: New 3-story, type V-A construction, 46,623 SF, group R-2, 36 unit Multifamily building. Special inspection req. - concrete, soils, Fire-resistant penetration & joints. Deferred submittal: Roof trusses. Deferred 13R fire sprinklers, fire alarm and electric vehicle gates. Water meters: (1) 2-inch Domestic. REF: PMT25-21560 for civil improvement and water meters. Approved with comments. Results in CoO.
New Building of 276-units multi-family development comprising of (9) 3-stories multifamily buildings. BLDG 10: New 3-story, type V-A construction, 46,623 SF, group R-2, 36 unit Multifamily building. Special inspection req. - concrete, soils, Fire-resistant penetration & joints. Deferred submittal: Roof trusses. Deferred 13R fire sprinklers, fire alarm and electric vehicle gates. Water meters: (1) 2-inch Domestic. REF: PMT25-21560 for civil improvement and water meters. Approved with comments. Results in CoO.
New Building of 276-units multi-family development comprising of (9) 3-stories multifamily buildings. BLDG 9: New 3-story, type V-A construction, 46,623 SF, group R-2, 36 unit Multifamily building. Special inspection req. - concrete, soils, Fire-resistant penetration & joints. Deferred submittal: Roof trusses. Deferred 13R fire sprinklers, fire alarm and electric vehicle gates. Water meters: (1) 2-inch Domestic. REF: PMT25-21560 for civil improvement and water meters. Approved with comments. Results in CoO.
New Building of 276-units multi-family development comprising of (9) 3-stories multifamily buildings. BLDG 6: New 3-story, type V-A construction, 46,623 SF, group R-2, 36 unit Multifamily building. Special inspection req. - concrete, soils, Fire-resistant penetration & joints. Deferred submittal: Roof trusses. Deferred 13R fire sprinklers, fire alarm and electric vehicle gates. Water meters: (1) 2-inch Domestic. REF: PMT25-21560 for civil improvement and water meters. Approved with comments. Results in CoO.
New Building of 276-units multi-family development comprising of (9) 3-stories multifamily buildings. BLDG 8: New 3-story, type V-A construction, 46,623 SF, group R-2, 36 unit Multifamily building. Special inspection req. - concrete, soils, Fire-resistant penetration & joints. Deferred submittal: Roof trusses. Deferred 13R fire sprinklers, fire alarm and electric vehicle gates. Water meters: (1) 2-inch Domestic. REF: PMT25-21560 for civil improvement and water meters. Approved with comments. Results in CoO.
New Building of 276-units multi-family development comprising of (9) 3-stories multifamily buildings. BLDG 2: New 3-story, type V-A construction, 46,623 SF, group R-2, 36 unit Multifamily building. Special inspection req. - concrete, soils, Fire-resistant penetration & joints. Deferred submittal: Roof trusses. Deferred 13R fire sprinklers, fire alarm and electric vehicle gates. Water meters: (1) 2-inch Domestic. REF: PMT25-21560 for civil improvement and water meters. Approved with comments. Results in CoO.
BLDG 3: New 3-story, type V-A construction, 31,104 SF, group R-2, 24 unit Multifamily building. Special inspection req. - concrete, soils, Fire-resistant penetration & joints. Deferred submittal: Roof trusses. Deferred 13R fire sprinklers, and fire alarm. REF: PMT25-21560 for civil improvement and water meters. Approved with comments. Results in CoO.
New 2,887 SF Type V-B clubhouse building with a 225 SF covered entrance and 672 SF covered porch. Scope includes leasing office, reception, coffee lounge, business center, restrooms, MEP systems, and finishes. New 400 AMP electric meter. Deferred submittals include fire sprinklers, fire alarm, access control, and truss calculations. Special inspections required for soils and concrete. Results in a CoO.
New 1,842 SF. Construction type V-B. Group B Fitness Center. Scope includes exercise rooms, lobby, pet spa, janitor room, restrooms, MEP systems, and interior finishes. Special inspections required for soils, concrete, masonry, and post-installed anchors. Deferred submittals include fire sprinklers, fire alarm, and truss calculations. Reviewed as noted. Results in CoO.
BLDG 5: New 3-story, type V-A construction, 15,585 SF, group R-2, 12 unit Multifamily building. Special inspection req. - concrete, soils, Fire-resistant penetration & joints. Deferred submittal: Roof trusses. Deferred 13R fire sprinklers, fire alarm. REF: PMT25-21560 for civil improvement and water meters. Approved with comments. Results in CoO.
New 900 SF Type V-B mail kiosk and maintenance building. Scope includes a required 1-hour fire-resistance-rated east exterior wall for separation from Building 2, electrical systems, and interior and exterior finishes. Deferred truss calculations and fire sprinkler system. No new meters. Fire sprinkler monitoring shall be submitted under a separate related permit. Special inspections required for soils, concrete, and fire-resistance-rated assemblies. Results in a CoO.