Construct (1) new Type C building. Type V-B construction. Each building is 476 SF with a 105 SF patio. The building includes (1) one-bedroom dwelling unit, complete interior and exterior construction, and associated building systems. Deferred submittal for engineered I-joist design. Special inspections required for soils, concrete, masonry, wood, post-tensioned concrete, post-installed anchors, fire-rated assemblies, and spray foam insulation. Reviewed as noted. Results in CoO.
Maricopa County · APN 13553003C
109 N ALMA SCHOOL RD 101
Mesa, AZ, 85201 · Vacant
Property record
- Property type:
- VACANT
- Total sqft:
- 14,201
- Assessed value:
- $31,755
- Full cash value:
- $211,700
Water supply
- Management area:
- Phoenix AMA
- Water provider:
- City Of Mesa
Sales history
- Oct 1, 2023$1,025,000OTHERSD
Neighborhood
- Owner-occupied:
- 39% of homes
- Median home value:
- $292,600
- Median household income:
- $63,725
- Median year built:
- 1981
Permits (15, last 90 days)
BLDG 7 UNITS 110 & 111 Construction of (4) new Duplex Type B buildings, Type V-B construction. Each building is 952 SF with a 209 SF patio. Each building includes two (2) one-bedroom dwelling units separated by required 1-hour fire-rated partitions, complete interior and exterior construction, and associated building systems. All off-site improvements and street frontage landscaping must be installed in the first phase of construction. Ref PMT25-08440 for civil improvements and landscaping. Deferred submittal for engineered I-joist design. Special inspections required for soils, concrete, masonry, wood, post-tensioned concrete, post-installed anchors, fire-rated assemblies, and spray foam insulation. Reviewed as noted. Results in CoO.
BLDG 11 UNITS 118 & 119 Construction of (4) new Duplex Type B buildings, Type V-B construction. Each building is 952 SF with a 209 SF patio. Each building includes two (2) one-bedroom dwelling units separated by required 1-hour fire-rated partitions, complete interior and exterior construction, and associated building systems. All off-site improvements and street frontage landscaping must be installed in the first phase of construction. Ref PMT25-08440 for civil improvements and landscaping. Deferred submittal for engineered I-joist design. Special inspections required for soils, concrete, masonry, wood, post-tensioned concrete, post-installed anchors, fire-rated assemblies, and spray foam insulation. Reviewed as noted. Results in CoO.
BLDG 10 UNIT 116 & 117 Construction of (6) new Duplex Type B buildings, Type V-B construction. Each building is 952 SF with a 209 SF patio. Each building includes two (2) one-bedroom dwelling units separated by required 1-hour fire-rated partitions, complete interior and exterior construction, and associated building systems. Deferred submittal for engineered I-joist design. Special inspections required for soils, concrete, masonry, wood, post-tensioned concrete, post-installed anchors, fire-rated assemblies, and spray foam insulation. Reviewed as noted. Results in CoO. Civil under separate permit PMT25-08440.
BLDG 8 UNIT 112 & 113 Construction of (6) new Duplex Type B buildings, Type V-B construction. Each building is 952 SF with a 209 SF patio. Each building includes two (2) one-bedroom dwelling units separated by required 1-hour fire-rated partitions, complete interior and exterior construction, and associated building systems. Deferred submittal for engineered I-joist design. Special inspections required for soils, concrete, masonry, wood, post-tensioned concrete, post-installed anchors, fire-rated assemblies, and spray foam insulation. Reviewed as noted. Results in CoO. Civil under separate permit PMT25-08440.
BLDG 9 UNITS 114 & 115 Construction of (4) new Duplex Type B buildings, Type V-B construction. Each building is 952 SF with a 209 SF patio. Each building includes two (2) one-bedroom dwelling units separated by required 1-hour fire-rated partitions, complete interior and exterior construction, and associated building systems. All off-site improvements and street frontage landscaping must be installed in the first phase of construction. Ref PMT25-08440 for civil improvements and landscaping. Deferred submittal for engineered I-joist design. Special inspections required for soils, concrete, masonry, wood, post-tensioned concrete, post-installed anchors, fire-rated assemblies, and spray foam insulation. Reviewed as noted. Results in CoO.
BLDG 5 UNITS 107 & 108 Construction of (6) new Duplex Type B buildings, Type V-B construction. Each building is 952 SF with a 209 SF patio. Each building includes two (2) one-bedroom dwelling units separated by required 1-hour fire-rated partitions, complete interior and exterior construction, and associated building systems. Deferred submittal for engineered I-joist design. Special inspections required for soils, concrete, masonry, wood, post-tensioned concrete, post-installed anchors, fire-rated assemblies, and spray foam insulation. Reviewed as noted. Results in CoO. Civil under separate permit PMT25-08440.
BLDG 4 UNITS 105 & 106 Construction of (6) new Duplex Type B buildings, Type V-B construction. Each building is 952 SF with a 209 SF patio. Each building includes two (2) one-bedroom dwelling units separated by required 1-hour fire-rated partitions, complete interior and exterior construction, and associated building systems. Deferred submittal for engineered I-joist design. Special inspections required for soils, concrete, masonry, wood, post-tensioned concrete, post-installed anchors, fire-rated assemblies, and spray foam insulation. Reviewed as noted. Results in CoO. Civil under separate permit PMT25-08440.
BLDG 12 UNIT 120 & 121 Construction of (6) new Duplex Type B buildings, Type V-B construction. Each building is 952 SF with a 209 SF patio. Each building includes two (2) one-bedroom dwelling units separated by required 1-hour fire-rated partitions, complete interior and exterior construction, and associated building systems. Deferred submittal for engineered I-joist design. Special inspections required for soils, concrete, masonry, wood, post-tensioned concrete, post-installed anchors, fire-rated assemblies, and spray foam insulation. Reviewed as noted. Results in CoO. Civil under separate permit PMT25-08440.
BLDG 2 UNITS 101 &102 Construction of (6) new Duplex Type B buildings, Type V-B construction. Each building is 952 SF with a 209 SF patio. Each building includes two (2) one-bedroom dwelling units separated by required 1-hour fire-rated partitions, complete interior and exterior construction, and associated building systems. (1) electric meter, (1) 1-inch landscape meter, and (1) 1.5 inch domestic water meter. Deferred submittal for engineered I-joist design. Special inspections required for soils, concrete, masonry, wood, post-tensioned concrete, post-installed anchors, fire-rated assemblies, and spray foam insulation. Reviewed as noted. Results in CoO. Civil under separate permit PMT25-08440.
BLDG 3 UNITS 103 & 104 Construction of (4) new Duplex Type B buildings, Type V-B construction. Each building is 952 SF with a 209 SF patio. Each building includes two (2) one-bedroom dwelling units separated by required 1-hour fire-rated partitions, complete interior and exterior construction, and associated building systems. All off-site improvements and street frontage landscaping must be installed in the first phase of construction. Ref PMT25-08440 for civil improvements and landscaping. Deferred submittal for engineered I-joist design. Special inspections required for soils, concrete, masonry, wood, post-tensioned concrete, post-installed anchors, fire-rated assemblies, and spray foam insulation. Reviewed as noted. Results in CoO.
Community Center Foundation Permit Only. Total enclosed and conditioned building area of 3,736 SF, type VB construction. REF: PMT25-23753 for Bldg. Approved with comments. Results in CoC.
Foundation and under-slab plumbing Permit Only. (6) 952 SF, construction type V-B, R-2 occupancy apartments with 209 SF patios. Special Inspections Req for Soils and Post-Tensioned Concrete. Results in CoC.
Foundation and under-slab plumbing Permit Only. (4) 952 SF, construction type V-B, R-2 occupancy apartments with 209 SF patios. Special Inspections Req for Soils and Post-Tensioned Concrete. Results in CoC.
Foundation Permit Only. (1) 476 SF, construction type V-B, R-2 occupancy apartment with 105 SF patio. Special Inspections Req for Soils and Post-Tensioned Concrete. Results in CoC.
Showing the last 90 days — Pro shows the full history. See pricing
Want to see permits older than 90 days? Sign up free.
Sign up — 14-day Pro trial