Group M occupancy. Type V-B construction. 2,299 SF. Occupant load 59. Shell building permit PMT25-04231. New tenant build out contacts/eyeglasses sales office in a new grey shell building. Infill concreate slab in marked area. Spot weld shut one of two rear exit doors. New partition walls to create consultation rooms, storage rooms, break room, and ADA compliant restroom. New mechanical RTUs (2), supply/return air ducting, diffusers, grilles and (2) exhaust fans. New water lines, wastewater lines, water heater, recirculation pump, and plumbing fixtures. New architectural and MEP. Special inspection required: epoxy. Deferred fire sprinklers. Approved as noted. Results in CofO.
Maricopa County · APN 22082018G
10861 E SOUTHERN AVE SUITE 105
Mesa, AZ
Permit applied — not yet issued
Filed 102d ago · well past the typical ~16d window — likely revising or phased
Based on mesa's typical applied→issued time — the earliest a supplier can engage, before the slab is poured.
Permits (10, last 90 days)
Group B occupancy. 3,060 SF. Type V-B construction. Occupant load of 27. New partition walls to create exam rooms, ward, open treatment area, x-ray room, surgery room, pharmacy, 2-ADA compliant restrooms, break room, offices, and lobby/reception area to create veterinary office in new shell building (PMT25-04230). New concrete slab to tie into existing slab. New plumbing water lines, waste lines, and medical gas lines. New supply air ducting, return air ducting, and exhaust ducting with roof top penetrations. 2 - existing heat pump RTUs. New lighting fixtures, emergency lighting, and electrical 400A 3 phase meter. New architectural, structural, and MEP. Special inspections required: concrete construction and medical gas/vacuum systems. Deferred fire sprinklers. Results in CoO.
Group B occupancy. Type V-B construction. 1,507 SF. Occupant load 44. New restaurant buildout in a new shell building. Existing 1-hour rated demising wall. New partition walls to create (2) ADA compliant restrooms, customer area, and prep area. New mechanical supply/return air ducting, exhaust air ducts, and roof top exhaust air fan. New plumbing fixtures, water lines, waste lines, and gas powered water heaters. New 400A 3 phase electrical meter. Special inspections required: concrete construction. Deferred fire sprinklers. Results in CofO.
Tenant improvement for existing 1,296 SF, V-B construction, B occupancy suite for an ice cream shop with 576 Sf exist outdoor dining area. Building is only access by employees, and modification include interior wall to create an ice cream production and dipping area and (1) ADA restroom with associated MEP. Patio railing part of shell permit. Deferred fire sprinklers. REF: PMT25-04232 Shops D Shell. Results in CoO.
Group B occupancy. Type V-B construction. 5,000 SF. Occupant load 53. Shell building construction under permit PMT25-04231. New partition walls to create waiting room, front office, 2-ADA compliant restrooms, lounge, x-ray rooms, equipment room, sterilization, storage, and exam rooms in new dentist office. 4-existing mechanical heat pump RTU's. New mechanical supply, return air, and exhaust ducts. New exhaust penetrations through the roof. New plumbing water lines, waste lines, vacuum system, and amalgam separator. New electrical lighting, emergency lights, exit signs, and receptacles. Deferred fire sprinklers. Results in CoO.
Tenant improvement of existing 2400 SF, type VB construction, B occupancy vacation suite for New Nail Salon. Modification include new interior partition to create (2) ADA restroom, Facial and Utility room and area separation for Lobby and spa area. Modification include mechanical duct from existing RTU, plumbing and electrical lighting and power. REF: PMT25-04232 Medina Station Shops D shell. Deferred fire sprinklers. Results in CoO.
1. INSTALLATION OF A DEDICATED FUNCTION CONTROL UNIT FOR SPRINKLER WATERFLOW AND SUPERVISORY MONITORING. THIS PERMIT IS RELATED TO PMT25-22293
DEVELOPMENT FOR NEW RESTAURANT AND RETAIL USERS. THE PROPOSED USES ARE APPROVED USEIN PAD ZONING PER CITY OF MESA DEVELOPMENT CODE. WE ARE PROPOSING CONSTRUCTION OF A SINGLE-STORY BUILDING WITH A TOTAL BUILDING AREA APPROXIMATELY 3,000 S.F. WITH OVERHANGS TOTALING 1,462 S.F. Including fire sprinkler and fire alarm systems.
0Install two set of internally illuminated face lit channel letters on east and south elevations US BANK 44.8 Sq Ft each. Install two set of internally illuminated face lit channel letters on north and west elevations US BANK 27.9 Sq Ft each. Install one reface for existing internally illuminated monument sign. Signs shall be installed per NEC 2023 with UL listed components.
Installation of one store front channel illuminated letterset BOOT BARN 125.6 Sq Ft. Non-illuminated double sided blade sign 3.5 sq ft, no permit required per 11-47-2.A.2. Signs shall be installed per NEC 2023 with UL listed components