WARMTrench from city meter to inlet at side of home approximately 100 feet
Install new 1 inch gas main with code approved PE risers and PE piping.
Reduce 1 inch down to three-quarter inch and cap at home side for pressure test, install pressure gauge and set the 15 pounds per code requirements
Install code approved, yellow tracer wire for entire length of new gas line.
Riser at house side will have a ball valve to terminate for testing and isolation for install of home
Install new 3/4” gas line into home to connect to all gas fixtures.
Permit #TC-RES-0526-02735 · tucson · issued May 29, 2026
$0
Inspections
Trench from city meter to inlet at side of home approximately 100 feet Install new 1 inch gas main with code approved PE risers and PE piping. Reduce 1 inch down to three-quarter inch and cap at home side for pressure test, install pressure gauge and set the 15 pounds per code requirements Install code approved, yellow tracer wire for entire length of new gas line. Riser at house side will have a ball valve to terminate for testing and isolation for install of home Install new 3/4” gas line into home to connect to all gas fixtures.
0Jobe & Sons Plumbing LLC (Likely)