This report identifies permits and documentation required to obtain a permit for removal or restoration of the building to a safe condition. This report is not an appraisal for financial claims. The building inspector may require portions of the building or other debris to be removed to allow evaluation of the damage. Structural shoring and additional lighting may also be required. Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. DATE: 5/13/2026 ADDRESS: 7121 E LAGUNA AZUL AVE MESA DAMAGED CAUSED BY: Fire INSPECTED BY: Richard Lemcke The inspection of the site identified the following: Please note that before a damage permit is issued an estimate showing the Company doing the work, the subject address, scope of work, materials, and labor from either the contractor or the insurance company will be required. A written scope of work is required to approximate the cost of the permit, verbal estimations shall not be used. A completed Contractor Verification Form must also be submitted prior to being issued a permit. This structure is to be restored like for like construction in compliance with 2023 NEC, 2024 IRC/IBC requirements. Any alterations or changes will require submitting plans before any restoration can begin. During the damage inspection the following was observed: Structural members have been damaged by and will need an engineers observation asletter. Electrical sustained damage to several home runs panel need to be replaced All damaged wires must be replaced per 2023 NEC/2024 IRC. Mechanical equipment/ducts sustained minor damage. Will need to clean/repair ductwork Plumbing does not appear to be damaged Note: Any structural members charred to a depth of 1/8” or greater are to be replaced. All plumbing, electrical and mechanical systems damaged by heat are to be replaced. A. Building is: Residential B. Building permits and inspections are required for the following phase (s) of construction: 1. Structural Yes 2. Electrical Yes 3. Mechanical Yes 4. Plumbing No 5. Construction Plans Required No
7121 E LAGUNA AZUL AVE
Property record
- Property type:
- RESIDENTIAL
- Year built:
- 1995
- Living area:
- 1,980 sqft
- Total sqft:
- 7,584
- Subdivision:
- SUPERSTITION SPRINGS VILLAGE UNIT ONE
- Assessed value:
- $41,520
- Full cash value:
- $415,200
Owner of record
LOZON AUSTIN/VEITCH BRIANNA
7121 E LAGUNA AZUL AVE, MESA AZ 85209
APN 30907216 · Maricopa County Assessor
Water supply
- Management area:
- Phoenix AMA
- Water provider:
- City Of Mesa
Arizona Department of Water Resources
Sales history
- Dec 1, 2022$417,600CONVENTIONALLOZON AUSTIN/VEITCH BRIANNAWD
Maricopa County sales affidavits · sale dates resolve to month
Permits (1, last 90 days)
WARMThis report identifies permits and documentation required to obtain a permit for removal or restoration of the building to
a safe condition. This report is not an appraisal for financial claims.
The building inspector may require portions of the building or other debris to be removed to allow evaluation of the
damage. Structural shoring and additional lighting may also be required.
Before demolition or restoration can begin, an approved method of trash containment and removal must be in place.
DATE: 5/13/2026
ADDRESS: 7121 E LAGUNA AZUL AVE MESA
DAMAGED CAUSED BY: Fire
INSPECTED BY: Richard Lemcke
The inspection of the site identified the following: Please note that before a damage permit is issued an estimate
showing the Company doing the work, the subject address, scope of work, materials, and labor from either the
contractor or the insurance company will be required. A written scope of work is required to approximate the
cost of the permit, verbal estimations shall not be used. A completed Contractor Verification Form must also
be submitted prior to being issued a permit. This structure is to be restored like for like construction in
compliance with 2023 NEC, 2024 IRC/IBC requirements. Any alterations or changes will require submitting
plans before any restoration can begin. During the damage inspection the following was observed: Structural
members have been damaged by and will need an engineers observation asletter. Electrical sustained damage
to several home runs panel need to be replaced All damaged wires must be replaced per 2023 NEC/2024 IRC.
Mechanical equipment/ducts sustained minor damage. Will need to clean/repair ductwork Plumbing does not
appear to be damaged
Note: Any structural members charred to a depth of 1/8” or greater are to be replaced. All plumbing, electrical and
mechanical systems damaged by heat are to be replaced.
A. Building is: Residential
B. Building permits and inspections are required for the following phase (s) of construction:
1. Structural Yes 2. Electrical Yes 3. Mechanical Yes 4. Plumbing No 5. Construction Plans Required No
Permit #PMT26-09381 · mesa · issued May 14, 2026
$95,011
Issued
Want to see permits older than 90 days? Sign up free.
Sign up — 14-day Pro trial