Before demolition or restoration can begin, an approved method of trash containment and removal must be in place. DATE: 4/28/2026 ADDRESS: 421 N ALMA SCHOOL RD MESA DAMAGED CAUSED BY: Fire INSPECTED BY: Richard Lemcke The inspection of the site identified the following: Please note that before a damage permit is issued an estimate showing the Company doing the work, the subject address, scope of work, materials, and labor from either the contractor or the insurance company will be required. A written scope of work is required to approximate the cost of the permit, verbal estimations shall not be used. A completed Contractor Verification Form must also be submitted prior to being issued a permit. This structure is to be restored like for like construction in compliance with 2017 NEC, 2018 IRC/IBC requirements. Any alterations or changes will require submitting plans before any restoration can begin. During the damage inspection the following was observed: All repairs must be performed in compliance with the currently adopted codes. Structural members have been damaged by and will need an engineers observation letter. Electrical sustained minor damage. The panel may need to be replaced if determined that the electrician can?t bring it to current codes. Mechanical equipment/ducts sustained minor damage. Will need to clean/repair ductwork Plumbing does not appear to be damaged Note: Any structural members charred to a depth of 1/8” or greater are to be replaced. All plumbing, electrical and mechanical systems damaged by heat are to be replaced. A. Building is: Commercial B. Building permits and inspections are required for the following phase (s) of construction: 1. Structural Yes 2. Electrical Yes 3. Mechanical Yes 4. Plumbing No 5. Construction Plans Required No A Building Permit is not required for the repairs. Electrical service can be restored under the following conditions: If temporary power is issued, a repair permit for the damage must be obtained within 30 days from the date of the Damage Inspection Report, or the power will be disconnected. Natural gas service can only be restored after a gas test has been approved by the building inspector. If you have questions please call 480-644-4273.
421 N ALMA SCHOOL RD
Property record
- Property type:
- COMMERCIAL
- Year built:
- 1971
- Total sqft:
- 12,545
- Subdivision:
- LE-DON-JO ACRES
- Assessed value:
- $47,720
- Full cash value:
- $477,200
Owner of record
BROWN KELLY L/DYLIDIA
67 N FRASER DR E, MESA AZ 85203
APN 13530057A · Maricopa County Assessor
Water supply
- Management area:
- Phoenix AMA
- Water provider:
- City Of Mesa
Arizona Department of Water Resources
Sales history
- May 1, 2005$188,700BROWN KELLY L/DYLIDIAJC
Maricopa County sales affidavits · sale dates resolve to month
Neighborhood
- Owner-occupied:
- 39% of homes
- Median home value:
- $292,600
- Median household income:
- $63,725
- Median year built:
- 1981
ZIP 85201 · U.S. Census ACS 2023 5-year
Permits (1, last 90 days)
HOTBefore demolition or restoration can begin, an approved method of trash containment and removal must be in place.
DATE: 4/28/2026
ADDRESS: 421 N ALMA SCHOOL RD MESA
DAMAGED CAUSED BY: Fire
INSPECTED BY: Richard Lemcke
The inspection of the site identified the following: Please note that before a damage permit is issued an estimate
showing the Company doing the work, the subject address, scope of work, materials, and labor from either the
contractor or the insurance company will be required. A written scope of work is required to approximate the
cost of the permit, verbal estimations shall not be used. A completed Contractor Verification Form must also
be submitted prior to being issued a permit. This structure is to be restored like for like construction in
compliance with 2017 NEC, 2018 IRC/IBC requirements. Any alterations or changes will require submitting
plans before any restoration can begin. During the damage inspection the following was observed: All repairs
must be performed in compliance with the currently adopted codes. Structural members have been damaged
by and will need an engineers observation letter. Electrical sustained minor damage. The panel may need to be
replaced if determined that the electrician can?t bring it to current codes. Mechanical equipment/ducts
sustained minor damage. Will need to clean/repair ductwork Plumbing does not appear to be damaged
Note: Any structural members charred to a depth of 1/8” or greater are to be replaced. All plumbing, electrical and
mechanical systems damaged by heat are to be replaced.
A. Building is: Commercial
B. Building permits and inspections are required for the following phase (s) of construction:
1. Structural Yes 2. Electrical Yes 3. Mechanical Yes 4. Plumbing No 5. Construction Plans Required No
A Building Permit is not required for the repairs.
Electrical service can be restored under the following conditions: If temporary power is issued, a repair permit for
the damage must be obtained within 30 days from the date of the Damage Inspection Report, or the power will
be disconnected.
Natural gas service can only be restored after a gas test has been approved by the building inspector.
If you have questions please call 480-644-4273.